31 R E L A S T ® D E S I G N M A N U A L C Design Verification of control perimeter r crit 522 mm *EN 1992-1-1 6 4 1 u 1 4379 mm β 1 1 *Inner column v Ed β * V Ed u 1 * d *EN 1992-1-1 6 4 3 6 38 0 75 Nmm 2 k 1 88 v min 0 0525 γ c * √ k 3 * f ck *EN 1992-1-1 6 2 2 6 3 0 0525 1 5 * √ 1 88 3 * 25 Nmm 2 0 45 Nmm 2 C Rd c 0 18 γ c 0 12 *NA to EN 1992-1-1-2004 6 4 4 1 σ cp 0 *No prestressing v Rd c max[C Rd c * k * 100 * ρ l x * f ck 1 3 v min ] *EN 1992-1-1 6 4 4 6 47 max[0 12 * 1 88 * 100 * 0 0057 * 25 Nmm 2 1 3 0 45 Nmm 2 ] 0 55 Nmm 2 B RELAST ® configuration s min 100 mm *Z-15 1-345 Annex 3 c min 85 mm *Z-15 1-345 Annex 3 s r min 100 mm *Minimum radial spacing of screws s r max 195 75 mm *Maximum radial spacing of screws s r chosen 190 mm *Chosen radial spacing of screws s c min 78 3 mm *Minimum spacing of first row of screws to the column s c max 130 5 mm *Maximum spacing of first row of screws to the column s c chosen 95 mm *Chosen spacing of first row of screws to the column