48 R E L A S T ® D E S I G N M A N U A L 6c Remove dust from surrounding metal parts 6d Fill the cap nut up to 50% with RELAST ® composite mortar 6e Screw on the cap nut Bonding compound must have emerged visibly after screwing on Remove protruding mortar G Procedure for cutting standard RELAST ® sizes on site Standard hole drilling Stepped hole drilling 6a Screw in the composite anchor screw to the specified depth Fit pressure distribution washer wedge lock washer and nut Tighten the nut with the specified torque 6b Cut the protruding thread with a power cutter above the nut Use a thin cutting disc if possible 5 PRODUCT INFO