5 R E L A S T ® D E S I G N M A N U A L The design approach of RELAST ® for postinstalled shear and punching shear reinforcement is according to DIN EN 1992-1-1 in combination with the relevant annex of the document Through extensive testing and research at the University of Innsbruck Unit of Concrete Structures and Bridge Design RELAST ® was found to increase shear capacity in reinforced concrete elements by 100% and punching shear capacity by 40% The design does not take into account existing reinforcement in concrete elements Figure 3 Concrete screw pressure distribution washer wedge lock washer and hexagon nut Figure 2 RELAST ® loadcarrying capacity [4] Fs